Radon system monitor installation
Radon system monitor installation










radon system monitor installation

There is a missing one-way flow valve, water trap, or other control device installed in or on the discharge line to prevent outside air from entering the system. The piping is less than 4 inches in diameter. The external run is subject to sub-freezing and it is not protected to prevent the risk of vent pipe freeze-up. There are pipe connections that are not permanently sealed with adhesives. a missing one-way flow valve, water trap, or other control device installed in or on the discharge line to prevent outside air from entering the system while allowing water to flow out of the system when a radon mitigation system is designed to draw soil gas from a perimeter drain tile loop that discharges water through a drain line to daylight or to a soak-away.radon vent pipes not installed in a configuration that ensures that any rain water or condensation within the pipes drains downward into the ground beneath the slab or soil-gas retarder membrane and.radon vent pipes not designed with removable or flexible couplings to facilitate removal of the sump pit cover for sump pump maintenance.radon vent pipes blocking access to any areas requiring maintenance or inspection.reducers that are installed in the direction of air flow.pipe and fitting connections of different materials.piping subjected to weather or physical damage that is not Schedule 40.piping that is less than 4 inches in diameter.piping that is not PVC, ABS, or downspout (outside).attic and external runs subject to sub-freezing that are not protected to prevent the risk of vent pipe freeze-up.joints and connections that are not airtight.joints and connections that are not permanently sealed with adhesives.submersible pumps not used in systems that use sump pits as the suction point for active soil depressurization if sump pumps are needed.penetrations of pipes or ducts that penetrate a firewall or other fire resistance-rated wall or floor not protected in accordance with applicable building, mechanical, fire, or electrical codes.The inspector should inspect the area around the HRV system for the presence of asbestos-like material. The inspector should inspect the crawlspace for the presence of asbestos-like material and combustible fuel-served appliances located within the crawlspace or in spaces adjacent to the crawlspace. The inspector should inspect hollow-block walls for cracks, openings, and open top-courses. Hollow-Block Wall Depressurization Systems The inspector should inspect the vapor retarder used for sub-membrane depressurization systems (passive or active) for seams that are lapped less than 12 inches, and edges that are not sealed to the walls, posts, or other penetrations. The inspector should inspect drainpipes that extend to daylight for missing devices, such as one-way flow valves, or water traps that prevent outdoor air from entering the sub-slab area. The radon system is an active sub-slab depressurization system. The inspector shall describe the radon mitigation system as one of the following types: Over $75,000 Worth of Additional Benefits.












Radon system monitor installation